Home / Products / Ice Machine / Tube Ice Machine / 30 Ton Tube Ice Machine
  • 30 Ton Tube Ice Machine

30 Ton Tube Ice Machine

The DAXTRO TD300 is a 30 metric tons-per-day tube ice system for a commercial port-area ice seller. Its nominal 24-hour output is 30,000 kg, or about 1,250.0 kg/h as an arithmetic average, giving a practical starting point for matching production to a real operating schedule. The intended job is organizing high-volume tube-ice manufacturing around electricity, cold storage and dispatch costs. The supplied model sheet specifies 316L stainless steel at ice-contact surfaces, 304 stainless components elsewhere, and compressor choices from Bitzer, RefComp, Hanbell or Frascold. DAXTRO can configure the refrigeration and downstream handling package around the installation site rather than treating every facility as identical.


Share
  • Features
  • Parameters
  • Applications

What Makes This Model Suitable for Your Operation

TD300 sits in the 30 metric tons-per-day class for a high-volume production facility. Organizing high-volume tube-ice manufacturing around electricity, cold storage and dispatch costs. That matters because the size of the ice machine should follow real consumption, not the largest number on a catalogue page. Use the hottest-month demand, the busiest work shift, any confirmed resale orders and an appropriate storage reserve to select the plant. Compare the cost of unused capacity with the disruption of repeatedly buying ice when the operation is already at its limit. The next smaller TD200 is rated at 20 metric tons per day. It deserves attention when verified peak use stays comfortably below the 30 metric tons class and the smaller installation leaves enough reserve. This is the largest capacity listed in this supplied product family. For higher peak demand, discuss the layout and phasing of more than one production unit rather than assuming this model can be uprated.


Performance and Design Advantages

Ice Designed for the Actual Application

The hollow center makes each cylinder easy to recognize and convenient to sort or bag. It can be handled as loose ice or directed to a weighing-and-bagging station. In the TD300 application, the key is to specify a finished ice form that moves cleanly from the equipment to the customer or production step. The supplied sheet identifies the ice as Hollow cylindrical tube ice. An ice maker with the correct daily capacity is still the wrong purchase if the product is difficult to dispense, transfer or use in the buyer's process.


Equipment Options and Process Integration

The TD300 can be quoted with a compressor option selected from Bitzer, RefComp, Hanbell and Frascold. The model data lists an MCGS PLC-based control platform, 316L ice-contact material and 304 stainless steel for other listed components. Compressor packages, condenser arrangements and finished tube sizes are selected for the installed project; do not treat options as identical across capacities. For a complete project, plan a clean water-treatment line, hygienic discharge area, insulated receiving bin and, if ice is sold, a weigh-and-seal bagging station. The itemized quote should separate the base machine from selected accessories, so the buyer knows which components arrive together.


Operation and Reliability

TD300 should fit into the day-to-day work of a high-volume production facility, not add an unnecessary handling job. Protect the outlet and bin from dirty handling, and check the balance between ice harvest, bagging pace and cold storage. Agree on a cleaning schedule, operator access, drain points, water quality and spare-parts scope before installation. For this capacity, the practical checks are production stability, the clear discharge path and how quickly the operator can identify an alarm or isolate the unit for routine service.


How the Ice Production Process Works

Filtered water circulates over refrigerated vertical tubes. Ice grows around the tube walls; a controlled harvest releases hollow cylinders, which are cut to the specified length and discharged to the bin or next handling step. Finished tube diameter, cut length and water quality determine how the product works in a cup, fish box or retail bag.


Item

Specification / Selection Basis

Model

TD300

Nominal ice output

30,000 kg in 24 hours (30 metric tons per day)

Hourly production equivalent

Approximately 1,250.0 kg/h from the 24-hour rating; not a separate guaranteed hourly test

Ice form

Hollow cylindrical tube ice

Tube diameter and cut length

To be specified for the product and confirmed with the evaporator/harvest configuration

Ice-contact material

316L stainless steel, as stated in the model sheet

Other listed stainless parts

304 stainless steel, as stated in the model sheet

Compressor options

Bitzer / RefComp / Hanbell / Frascold; engineering selection at quotation

Controls

MCGS PLC-based operation; final HMI features per approved controls list

Refrigerant

R404A listed in source sheet; export configuration and destination compliance to be established

Power options

220 V single-phase or 380-415 V three-phase; 50/60 Hz listed as series options; actual suitability depends on model and installation

Certification references

CE and ISO 9001 stated in source sheet; request applicable project documents

Dimensions / total installed power / weight

Provided in the project-specific technical drawing and quotation

Output verification

Performance to be defined for actual ambient and inlet-water or process-fluid conditions

Technical note: Installed dimensions, power consumption and final equipment options are established by the approved project drawing and quotation.


Primary use

Primary use — Seafood and food processing. Deliver a measured ice flow to preparation or packing stations. Check product-contact hygiene, travel distance and ice consumption per production shift. For TD300, organizing high-volume tube-ice manufacturing around electricity, cold storage and dispatch costs. Calculate the daily requirement and the busiest withdrawal period before deciding how much ice should be held in reserve.


Additional commercial use

Additional commercial use — Bagged ice distribution. Weigh and seal uniform tube ice for nearby retailers, caterers or delivery customers. Match bag size, cold-room reserve and the bagging shift to the ice made over a full day. At 30 metric tons per day, plan whether the second application uses spare production capacity or needs a separate delivery window.


Other suitable processes

Other suitable processes — Fish market and seafood counters and beverage outlets and hospitality. Place loose tube ice around fish boxes and replenish stock through the trading day. Move hollow tube ice into insulated containers or suitable beverage service areas. For each use, document the ice form, hygiene requirements and the route from ice discharge to the actual point of use.


Operation Planning for This Model

A practical operating plan starts with when ice is needed, not when the machine is available to run. For TD300, map the first withdrawal, the most demanding part of the shift and the last planned dispatch. Then check whether engineered storage, controlled conveying and a dedicated dispatch route will protect production from short-term demand spikes. Where ice is used at several points, assign a person to the bin, tank or loading schedule rather than assuming nominal daily production equals instant delivery. Review water condition and equipment cleanliness as part of the regular shift handover.


Commercial and Technical Procurement Considerations

Before purchasing TD300, compare the full cost of delivered ice with on-site manufacture: bought-ice cost, delay risk, staff handling, water and electricity, cleaning, maintenance and storage. Do not assume the machine replaces every cold-chain cost or that the payback period will be the same at different sites. The business case is strongest when the plant can match peak daily dispatch, storage and maintenance access and avoid repeated supply interruptions. Ask for a quotation that identifies the installation scope, spare parts, warranty conditions and the operating assumptions behind the selected package.


Installation and Production Line Integration

Install the TD300 where operators can reach the electrical isolation point, water or process-fluid supply, cleaning area and ice-discharge route safely. A high-volume production facility normally needs engineered storage, controlled conveying and a dedicated dispatch route. The supporting system may include a clean water-treatment line, hygienic discharge area, insulated receiving bin and, if ice is sold, a weigh-and-seal bagging station. Before approving the layout, check drain capacity, access for service, incoming water or liquid quality, ambient design temperature and the length of each conveying or piping run. For multi-line plants, a drawing showing every receiving station and working shift is more useful than positioning the machine by the available floor area alone.


How to Choose Between Neighboring Models

TD300 is rated at 30 metric tons per day. The next smaller TD200 is rated at 20 metric tons per day. It deserves attention when verified peak use stays comfortably below the 30 metric tons class and the smaller installation leaves enough reserve. This is the largest capacity listed in this supplied product family. For higher peak demand, discuss the layout and phasing of more than one production unit rather than assuming this model can be uprated. Use a daily demand curve for the busiest season, the longest shift and any planned additional customers to decide. A smaller machine may cost less to buy yet leave too little reserve; a larger one may add handling and utility costs before the business can use the capacity. The final choice should compare the entire installed ice system, not the ice-machine list price.


Manufacturer Capabilities and Quality Assurance

DAXTRO presents its refrigeration manufacturing work as part of an integrated ice-making, storage and handling offering. The product source materials refer to a 30,000 m² facility in Zhongshan, 316L ice-contact construction, CE/ISO 9001 references and MCGS PLC control. For TD300, ask the supplier to provide the approved general-arrangement drawing, equipment schedule, application-specific material documentation, commissioning scope and maintenance instructions. The purchasing team should also request the model-specific inspection documents and an agreed plan for operator training and spare parts rather than assuming all equipment families have identical paperwork.


Information Needed for an Accurate Quotation

To quote TD300, send DAXTRO the application and expected 30 metric tons-per-day ice need; actual consumption in the busiest shift; peak-season delivery pattern; city and country; summer ambient conditions; incoming water or process-liquid data; and available electrical supply. Also specify a clean water-treatment line, hygienic discharge area, insulated receiving bin and, if ice is sold, a weigh-and-seal bagging station, required finished-ice characteristics, storage reserve and the location of the point of use. With those details, the project team can prepare a selected compressor/refrigeration package, utility schedule, layout drawing and an itemized quotation including optional equipment.


Frequently Asked Questions

What does the 30 ton/day rating mean for TD300?

It is a nominal 24-hour output of 30,000 kg, equivalent to an arithmetic average of 1,250.0 kg/h. It does not mean that exact production is guaranteed every hour or in every climate. Confirm the test conditions and site-temperature performance in the technical offer.

Who is the TD300 most suitable for?

It is designed as a production class for a commercial port-area ice seller. In the supplied product positioning, the main use is organizing high-volume tube-ice manufacturing around electricity, cold storage and dispatch costs. Verify the busiest operating period and ice-handling route before deciding whether this capacity matches your demand.

What finished tube ice specification should I request?

Tube diameter and cut length depend on the cup, bag or fish box; agree on a finished-ice specification before the evaporator and cutting arrangement are finalized.

Which equipment and site details must be confirmed before ordering TD300?

Confirm the final supply voltage and phase, refrigeration package, installed electrical load, footprint, water or process-liquid specification, ice storage, discharge connections and application-specific compliance documents. The series options in the model sheet are not a substitute for an approved project drawing.

When should I choose a different capacity instead of TD300?

The next smaller TD200 is rated at 20 metric tons per day. It deserves attention when verified peak use stays comfortably below the 30 metric tons class and the smaller installation leaves enough reserve. This is the largest capacity listed in this supplied product family. For higher peak demand, discuss the layout and phasing of more than one production unit rather than assuming this model can be uprated. Judge the choice using the highest-demand month and the busiest shift, not the average daily requirement over a year.

What supporting equipment is normally needed?

The full system may need a clean water-treatment line, hygienic discharge area, insulated receiving bin and, if ice is sold, a weigh-and-seal bagging station. The exact scope depends on whether ice is used beside the machine, transferred to another production line or dispatched as a commercial product. Ask for the auxiliaries on the same equipment list as the main ice machine.


Request a Technical Proposal

Planning a 30 metric tons-per-day tube ice project? Send us your site location, busiest daily ice requirement, available power supply and intended ice-handling process. DAXTRO can review the TD300 equipment choice and prepare a project proposal covering the machine, required auxiliaries, layout and commissioning scope. Request a quotation for the 30 Ton Tube Ice Machine today.


Contact
Follow Us

Sitemap