Home / Products / Ice Machine / Plate Ice Machine / 5 Ton Plate Ice Machine
  • 5 Ton Plate Ice Machine

5 Ton Plate Ice Machine

The DAXTRO PD50 is a 5 metric tons-per-day plate ice system for a diversified ice supplier or processing site. Its nominal 24-hour output is 5,000 kg, or about 208.3 kg/h as an arithmetic average, giving a practical starting point for matching production to a real operating schedule. The intended job is adding a plate-ice product to an existing cold-chain or ice-selling operation. The supplied model sheet specifies 316L stainless steel at ice-contact surfaces, 304 stainless components elsewhere, and compressor choices from Bitzer, RefComp, Hanbell or Frascold. DAXTRO can configure the refrigeration and downstream handling package around the installation site rather than treating every facility as identical.

Share
  • Features
  • Parameters
  • Typical B2B Applications
  • Frequently Asked Questions

What Makes This Model Suitable for Your Operation

PD50 sits in the 5 metric tons-per-day class for a working production site. Adding a plate-ice product to an existing cold-chain or ice-selling operation. That matters because the size of the ice machine should follow real consumption, not the largest number on a catalogue page. Use the hottest-month demand, the busiest work shift, any confirmed resale orders and an appropriate storage reserve to select the plant. Compare the cost of unused capacity with the disruption of repeatedly buying ice when the operation is already at its limit. The next smaller PD30 is rated at 3 metric tons per day. It deserves attention when verified peak use stays comfortably below the 5 metric tons class and the smaller installation leaves enough reserve. The next larger PD100 is rated at 10 metric tons per day. Compare it when peak demand, future lines or delivery commitments would run the PD50 close to its nominal daily rating.


Performance and Design Advantages

Ice Designed for the Actual Application

Flat plate pieces can be layered around products or broken to a handling size suited to transport. The intended piece size and distribution method should be agreed before layout planning. In the PD50 application, the key is to specify a finished ice form that moves cleanly from the equipment to the customer or production step. The supplied sheet identifies the ice as Flat dry ice plate or broken piece. An ice maker with the correct daily capacity is still the wrong purchase if the product is difficult to dispense, transfer or use in the buyer's process.


Equipment Options and Process Integration

The PD50 can be quoted with a compressor option selected from Bitzer, RefComp, Hanbell and Frascold. The model data lists an MCGS PLC-based control platform, 316L ice-contact material and 304 stainless steel for other listed components. Plate geometry, breakup and storage arrangements are project-specific and should be agreed alongside the refrigeration package. For a complete project, plan water treatment, ice-release and piece-handling equipment, insulated holding space and loading or conveying facilities. The itemized quote should separate the base machine from selected accessories, so the buyer knows which components arrive together.


Operation and Reliability

PD50 should fit into the day-to-day work of a working production site, not add an unnecessary handling job. Keep the route for released plate ice clear, and decide where larger pieces will be broken before they reach packed food or transport boxes. Agree on a cleaning schedule, operator access, drain points, water quality and spare-parts scope before installation. For this capacity, the practical checks are production stability, the clear discharge path and how quickly the operator can identify an alarm or isolate the unit for routine service.


How the Ice Production Process Works

Water freezes against refrigerated plate surfaces and forms flat ice sections. A controlled release transfers the plates or broken pieces to handling, storage or the downstream cooling process. Plate thickness, piece size and release method should be chosen for the receiving conveyor, containers and storage conditions.


ItemSpecification / Selection Basis
ModelPD50
Nominal ice output5,000 kg in 24 hours (5 metric tons per day)
Hourly production equivalentApproximately 208.3 kg/h from the 24-hour rating; not a separate guaranteed hourly test
Ice formFlat dry ice plate or broken piece
Finished plate / piece dimensionsDetermined by the approved ice-handling design
Ice-contact material316L stainless steel, as stated in the model sheet
Other listed stainless parts304 stainless steel, as stated in the model sheet
Compressor optionsBitzer / RefComp / Hanbell / Frascold; engineering selection at quotation
ControlsMCGS PLC-based operation; final HMI features per approved controls list
RefrigerantR404A listed in source sheet; export configuration and destination compliance to be established
Power options220 V single-phase or 380-415 V three-phase; 50/60 Hz listed as series options; actual suitability depends on model and installation
Certification referencesCE and ISO 9001 stated in source sheet; request applicable project documents
Dimensions / total installed power / weightProvided in the project-specific technical drawing and quotation
Output verificationPerformance to be defined for actual ambient and inlet-water or process-fluid conditions


Technical note: Installed dimensions, power consumption and final equipment options are established by the approved project drawing and quotation.

Primary use

Primary use — Fish transport and cold-chain logistics. Arrange plate pieces in transport containers or vehicle compartments. Balance piece size and handling effort with the route length and expected ice loss. For PD50, adding a plate-ice product to an existing cold-chain or ice-selling operation. Calculate the daily requirement and the busiest withdrawal period before deciding how much ice should be held in reserve.


Additional commercial use

Additional commercial use — Meat and food storage. Prepare larger ice pieces for staged cold handling and product storage. Confirm the size of pieces for practical lifting or conveyor movement. At 5 metric tons per day, plan whether the second application uses spare production capacity or needs a separate delivery window.


Other suitable processes

Other suitable processes — Seafood-processing plants and diversified commercial ice plants. Use plate ice in layers or targeted cooling points during processing and packing. Add plate ice to a production range that may already include cubes, tubes or blocks. For each use, document the ice form, hygiene requirements and the route from ice discharge to the actual point of use.


Operation Planning for This Model

A practical operating plan starts with when ice is needed, not when the machine is available to run. For PD50, map the first withdrawal, the most demanding part of the shift and the last planned dispatch. Then check whether an insulated receiving or holding area and a direct hand-off to the operating line will protect production from short-term demand spikes. Where ice is used at several points, assign a person to the bin, tank or loading schedule rather than assuming nominal daily production equals instant delivery. Review water condition and equipment cleanliness as part of the regular shift handover.


Commercial and Technical Procurement Considerations

Before purchasing PD50, compare the full cost of delivered ice with on-site manufacture: bought-ice cost, delay risk, staff handling, water and electricity, cleaning, maintenance and storage. Do not assume the machine replaces every cold-chain cost or that the payback period will be the same at different sites. The business case is strongest when the plant can match the line shift, stock reserve and equipment access and avoid repeated supply interruptions. Ask for a quotation that identifies the installation scope, spare parts, warranty conditions and the operating assumptions behind the selected package.


Installation and Production Line Integration

Install the PD50 where operators can reach the electrical isolation point, water or process-fluid supply, cleaning area and ice-discharge route safely. A working production site normally needs an insulated receiving or holding area and a direct hand-off to the operating line. The supporting system may include water treatment, ice-release and piece-handling equipment, insulated holding space and loading or conveying facilities. Before approving the layout, check drain capacity, access for service, incoming water or liquid quality, ambient design temperature and the length of each conveying or piping run. For multi-line plants, a drawing showing every receiving station and working shift is more useful than positioning the machine by the available floor area alone.


How to Choose Between Neighboring Models

PD50 is rated at 5 metric tons per day. The next smaller PD30 is rated at 3 metric tons per day. It deserves attention when verified peak use stays comfortably below the 5 metric tons class and the smaller installation leaves enough reserve. The next larger PD100 is rated at 10 metric tons per day. Compare it when peak demand, future lines or delivery commitments would run the PD50 close to its nominal daily rating. Use a daily demand curve for the busiest season, the longest shift and any planned additional customers to decide. A smaller machine may cost less to buy yet leave too little reserve; a larger one may add handling and utility costs before the business can use the capacity. The final choice should compare the entire installed ice system, not the ice-machine list price.


Manufacturer Capabilities and Quality Assurance

DAXTRO presents its refrigeration manufacturing work as part of an integrated ice-making, storage and handling offering. The product source materials refer to a 30,000 m² facility in Zhongshan, 316L ice-contact construction, CE/ISO 9001 references and MCGS PLC control. For PD50, ask the supplier to provide the approved general-arrangement drawing, equipment schedule, application-specific material documentation, commissioning scope and maintenance instructions. The purchasing team should also request the model-specific inspection documents and an agreed plan for operator training and spare parts rather than assuming all equipment families have identical paperwork.


Information Needed for an Accurate Quotation

To quote PD50, send DAXTRO the application and expected 5 metric tons-per-day ice need; actual consumption in the busiest shift; peak-season delivery pattern; city and country; summer ambient conditions; incoming water or process-liquid data; and available electrical supply. Also specify water treatment, ice-release and piece-handling equipment, insulated holding space and loading or conveying facilities, required finished-ice characteristics, storage reserve and the location of the point of use. With those details, the project team can prepare a selected compressor/refrigeration package, utility schedule, layout drawing and an itemized quotation including optional equipment.


What does the 5 ton/day rating mean for PD50?

It is a nominal 24-hour output of 5,000 kg, equivalent to an arithmetic average of 208.3 kg/h. It does not mean that exact production is guaranteed every hour or in every climate. Confirm the test conditions and site-temperature performance in the technical offer.


Who is the PD50 most suitable for?

It is designed as a production class for a diversified ice supplier or processing site. In the supplied product positioning, the main use is adding a plate-ice product to an existing cold-chain or ice-selling operation. Verify the busiest operating period and ice-handling route before deciding whether this capacity matches your demand.


What finished plate ice specification should I request?

Define whether the operation needs intact plates or smaller broken pieces and specify acceptable dimensions for conveyors, boxes and transport loads.


Which equipment and site details must be confirmed before ordering PD50?

Confirm the final supply voltage and phase, refrigeration package, installed electrical load, footprint, water or process-liquid specification, ice storage, discharge connections and application-specific compliance documents. The series options in the model sheet are not a substitute for an approved project drawing.


When should I choose a different capacity instead of PD50?

The next smaller PD30 is rated at 3 metric tons per day. It deserves attention when verified peak use stays comfortably below the 5 metric tons class and the smaller installation leaves enough reserve. The next larger PD100 is rated at 10 metric tons per day. Compare it when peak demand, future lines or delivery commitments would run the PD50 close to its nominal daily rating. Judge the choice using the highest-demand month and the busiest shift, not the average daily requirement over a year.


What supporting equipment is normally needed?

The full system may need water treatment, ice-release and piece-handling equipment, insulated holding space and loading or conveying facilities. The exact scope depends on whether ice is used beside the machine, transferred to another production line or dispatched as a commercial product. Ask for the auxiliaries on the same equipment list as the main ice machine.


Contact
Follow Us

Sitemap