Home / Products / Ice Machine / Cube Ice Machine / 20 Ton Cube Ice Machine
  • 20 Ton Cube Ice Machine

20 Ton Cube Ice Machine

The DAXTRO CD200 is a 20 metric tons-per-day cube ice system for a large packaged-ice plant or export-oriented supply operation. Its nominal 24-hour output is 20,000 kg, or about 833.3 kg/h as an arithmetic average, giving a practical starting point for matching production to a real operating schedule. The intended job is matching ice manufacture, bagging, cold storage and container-loading schedules. The supplied model sheet specifies 316L stainless steel at ice-contact surfaces, 304 stainless components elsewhere, and compressor choices from Bitzer, RefComp, Hanbell or Frascold. DAXTRO can configure the refrigeration and downstream handling package around the installation site rather than treating every facility as identical.


Share
  • Features
  • Parameters
  • Applications

What Makes This Model Suitable for Your Operation

CD200 sits in the 20 metric tons-per-day class for a multi-line or two-shift site. Matching ice manufacture, bagging, cold storage and container-loading schedules. That matters because the size of the ice machine should follow real consumption, not the largest number on a catalogue page. Use the hottest-month demand, the busiest work shift, any confirmed resale orders and an appropriate storage reserve to select the plant. Compare the cost of unused capacity with the disruption of repeatedly buying ice when the operation is already at its limit. The next smaller CD100 is rated at 10 metric tons per day. It deserves attention when verified peak use stays comfortably below the 20 metric tons class and the smaller installation leaves enough reserve. This is the largest capacity listed in this supplied product family. For higher peak demand, discuss the layout and phasing of more than one production unit rather than assuming this model can be uprated.


Performance and Design Advantages

Ice Designed for the Actual Application

Well-formed, solid cubes offer an attractive and consistent format for drinks, service buckets and measured bags. Handling, clarity and hygiene are just as important as capacity for customer-facing ice. In the CD200 application, the key is to specify a finished ice form that moves cleanly from the equipment to the customer or production step. The supplied sheet identifies the ice as Clear solid cube ice. An ice maker with the correct daily capacity is still the wrong purchase if the product is difficult to dispense, transfer or use in the buyer's process.


Equipment Options and Process Integration

The CD200 can be quoted with a compressor option selected from Bitzer, RefComp, Hanbell and Frascold. The model data lists an MCGS PLC-based control platform, 316L ice-contact material and 304 stainless steel for other listed components. Compressor selection, cube format and the water-treatment/harvest arrangement should be engineered to the destination climate and service requirement. For a complete project, plan treated potable-water supply, clean ice bins, a sanitary dispensing route and, where relevant, a bagging-and-cold-room system. The itemized quote should separate the base machine from selected accessories, so the buyer knows which components arrive together.


Operation and Reliability

CD200 should fit into the day-to-day work of a multi-line or two-shift site, not add an unnecessary handling job. Keep finished cubes in covered, sanitized storage, and avoid leaving dispensing points unprotected during busy service periods. Agree on a cleaning schedule, operator access, drain points, water quality and spare-parts scope before installation. For this capacity, the practical checks are production stability, the clear discharge path and how quickly the operator can identify an alarm or isolate the unit for routine service.


How the Ice Production Process Works

Clean water is fed to the refrigerated cube-forming surface. Ice grows into defined shapes, then a controlled harvest releases the cubes to a clean bin for direct beverage use or bagging. The clarity and appearance of finished cubes depend on water treatment, freezing conditions and post-harvest handling.


Item

Specification / Selection Basis

Model

CD200

Nominal ice output

20,000 kg in 24 hours (20 metric tons per day)

Hourly production equivalent

Approximately 833.3 kg/h from the 24-hour rating; not a separate guaranteed hourly test

Ice form

Clear solid cube ice

Finished cube size

Defined to suit the beverage, bag or dispenser format

Ice-contact material

316L stainless steel, as stated in the model sheet

Other listed stainless parts

304 stainless steel, as stated in the model sheet

Compressor options

Bitzer / RefComp / Hanbell / Frascold; engineering selection at quotation

Controls

MCGS PLC-based operation; final HMI features per approved controls list

Refrigerant

R404A listed in source sheet; export configuration and destination compliance to be established

Power options

220 V single-phase or 380-415 V three-phase; 50/60 Hz listed as series options; actual suitability depends on model and installation

Certification references

CE and ISO 9001 stated in source sheet; request applicable project documents

Dimensions / total installed power / weight

Provided in the project-specific technical drawing and quotation

Output verification

Performance to be defined for actual ambient and inlet-water or process-fluid conditions

Technical note: Installed dimensions, power consumption and final equipment options are established by the approved project drawing and quotation.


Primary use

Primary use — Bagged beverage ice. Prepare finished cubes for bagging and cold storage before distribution. Match bag size, packing throughput and cold-room capacity to the peak retail season. For CD200, matching ice manufacture, bagging, cold storage and container-loading schedules. Calculate the daily requirement and the busiest withdrawal period before deciding how much ice should be held in reserve.


Additional commercial use

Additional commercial use — Bars, cafés and drink shops. Use regular cubes in iced drinks where appearance and portion consistency are commercially important. Calculate peak drinks-per-hour and the ice per serving, not only the number of customers. At 20 metric tons per day, plan whether the second application uses spare production capacity or needs a separate delivery window.


Other suitable processes

Other suitable processes — Hotels and restaurants and food presentation and catering. Supply lobby drink stations, restaurant kitchens and guest ice buckets. Keep service ice available for display, chilled service and catering preparation. For each use, document the ice form, hygiene requirements and the route from ice discharge to the actual point of use.


Operation Planning for This Model

A practical operating plan starts with when ice is needed, not when the machine is available to run. For CD200, map the first withdrawal, the most demanding part of the shift and the last planned dispatch. Then check whether planned storage, conveying and shift-based dispatch will protect production from short-term demand spikes. Where ice is used at several points, assign a person to the bin, tank or loading schedule rather than assuming nominal daily production equals instant delivery. Review water condition and equipment cleanliness as part of the regular shift handover.


Commercial and Technical Procurement Considerations

Before purchasing CD200, compare the full cost of delivered ice with on-site manufacture: bought-ice cost, delay risk, staff handling, water and electricity, cleaning, maintenance and storage. Do not assume the machine replaces every cold-chain cost or that the payback period will be the same at different sites. The business case is strongest when the plant can match peak simultaneous withdrawals and changeover periods and avoid repeated supply interruptions. Ask for a quotation that identifies the installation scope, spare parts, warranty conditions and the operating assumptions behind the selected package.


Installation and Production Line Integration

Install the CD200 where operators can reach the electrical isolation point, water or process-fluid supply, cleaning area and ice-discharge route safely. A multi-line or two-shift site normally needs planned storage, conveying and shift-based dispatch. The supporting system may include treated potable-water supply, clean ice bins, a sanitary dispensing route and, where relevant, a bagging-and-cold-room system. Before approving the layout, check drain capacity, access for service, incoming water or liquid quality, ambient design temperature and the length of each conveying or piping run. For multi-line plants, a drawing showing every receiving station and working shift is more useful than positioning the machine by the available floor area alone.


How to Choose Between Neighboring Models

CD200 is rated at 20 metric tons per day. The next smaller CD100 is rated at 10 metric tons per day. It deserves attention when verified peak use stays comfortably below the 20 metric tons class and the smaller installation leaves enough reserve. This is the largest capacity listed in this supplied product family. For higher peak demand, discuss the layout and phasing of more than one production unit rather than assuming this model can be uprated. Use a daily demand curve for the busiest season, the longest shift and any planned additional customers to decide. A smaller machine may cost less to buy yet leave too little reserve; a larger one may add handling and utility costs before the business can use the capacity. The final choice should compare the entire installed ice system, not the ice-machine list price.


Manufacturer Capabilities and Quality Assurance

DAXTRO presents its refrigeration manufacturing work as part of an integrated ice-making, storage and handling offering. The product source materials refer to a 30,000 m² facility in Zhongshan, 316L ice-contact construction, CE/ISO 9001 references and MCGS PLC control. For CD200, ask the supplier to provide the approved general-arrangement drawing, equipment schedule, application-specific material documentation, commissioning scope and maintenance instructions. The purchasing team should also request the model-specific inspection documents and an agreed plan for operator training and spare parts rather than assuming all equipment families have identical paperwork.


Information Needed for an Accurate Quotation

To quote CD200, send DAXTRO the application and expected 20 metric tons-per-day ice need; actual consumption in the busiest shift; peak-season delivery pattern; city and country; summer ambient conditions; incoming water or process-liquid data; and available electrical supply. Also specify treated potable-water supply, clean ice bins, a sanitary dispensing route and, where relevant, a bagging-and-cold-room system, required finished-ice characteristics, storage reserve and the location of the point of use. With those details, the project team can prepare a selected compressor/refrigeration package, utility schedule, layout drawing and an itemized quotation including optional equipment.


Frequently Asked Questions

What does the 20 ton/day rating mean for CD200?

It is a nominal 24-hour output of 20,000 kg, equivalent to an arithmetic average of 833.3 kg/h. It does not mean that exact production is guaranteed every hour or in every climate. Confirm the test conditions and site-temperature performance in the technical offer.

Who is the CD200 most suitable for?

It is designed as a production class for a large packaged-ice plant or export-oriented supply operation. In the supplied product positioning, the main use is matching ice manufacture, bagging, cold storage and container-loading schedules. Verify the busiest operating period and ice-handling route before deciding whether this capacity matches your demand.

What finished cube ice specification should I request?

Specify the required cube dimensions, clarity expectations and how the finished cubes enter glasses, buckets or retail bags before the order is approved.

Which equipment and site details must be confirmed before ordering CD200?

Confirm the final supply voltage and phase, refrigeration package, installed electrical load, footprint, water or process-liquid specification, ice storage, discharge connections and application-specific compliance documents. The series options in the model sheet are not a substitute for an approved project drawing.

When should I choose a different capacity instead of CD200?

The next smaller CD100 is rated at 10 metric tons per day. It deserves attention when verified peak use stays comfortably below the 20 metric tons class and the smaller installation leaves enough reserve. This is the largest capacity listed in this supplied product family. For higher peak demand, discuss the layout and phasing of more than one production unit rather than assuming this model can be uprated. Judge the choice using the highest-demand month and the busiest shift, not the average daily requirement over a year.

What supporting equipment is normally needed?

The full system may need treated potable-water supply, clean ice bins, a sanitary dispensing route and, where relevant, a bagging-and-cold-room system. The exact scope depends on whether ice is used beside the machine, transferred to another production line or dispatched as a commercial product. Ask for the auxiliaries on the same equipment list as the main ice machine.


Request a Technical Proposal

Planning a 20 metric tons-per-day cube ice project? Send us your site location, busiest daily ice requirement, available power supply and intended ice-handling process. DAXTRO can review the CD200 equipment choice and prepare a project proposal covering the machine, required auxiliaries, layout and commissioning scope. Request a quotation for the 20 Ton Cube Ice Machine today.


Contact
Follow Us

Sitemap