What Makes This Model Suitable for Your Operation
BD200 sits in the 20 metric tons-per-day class for a multi-line or two-shift site. Preparing for several vessels to call on the same day and coordinating block release with loading crews. That matters because the size of the ice machine should follow real consumption, not the largest number on a catalogue page. Use the hottest-month demand, the busiest work shift, any confirmed resale orders and an appropriate storage reserve to select the plant. Compare the cost of unused capacity with the disruption of repeatedly buying ice when the operation is already at its limit. The next smaller BD100 is rated at 10 metric tons per day. It deserves attention when verified peak use stays comfortably below the 20 metric tons class and the smaller installation leaves enough reserve. The next larger BD300 is rated at 30 metric tons per day. Compare it when peak demand, future lines or delivery commitments would run the BD200 close to its nominal daily rating.
Performance and Design Advantages
Ice Designed for the Actual Application
Dense ice blocks are suited to organized storage and shipment where the customer values a durable ice form. Block weight and lifting method should be specified with the receiving operation. In the BD200 application, the key is to specify a finished ice form that moves cleanly from the equipment to the customer or production step. The supplied sheet identifies the ice as Solid ice block 5 to 50 kg. An ice maker with the correct daily capacity is still the wrong purchase if the product is difficult to dispense, transfer or use in the buyer's process.
Equipment Options and Process Integration
The BD200 can be quoted with a compressor option selected from Bitzer, RefComp, Hanbell and Frascold. The model data lists an MCGS PLC-based control platform, 316L ice-contact material and 304 stainless steel for other listed components. Confirm the block weight and mold arrangement, handling tools and condenser package for the delivered machine. For a complete project, plan clean feed water, block handling and lifting equipment, insulated storage and, where customers need loose ice, an appropriate ice-crushing station. The itemized quote should separate the base machine from selected accessories, so the buyer knows which components arrive together.
Operation and Reliability
BD200 should fit into the day-to-day work of a multi-line or two-shift site, not add an unnecessary handling job. Stage completed blocks and plan forklift or hoist access before the first major delivery; ice production cannot compensate for a blocked loading area. Agree on a cleaning schedule, operator access, drain points, water quality and spare-parts scope before installation. For this capacity, the practical checks are production stability, the clear discharge path and how quickly the operator can identify an alarm or isolate the unit for routine service.
How the Ice Production Process Works
Water freezes within a direct-cooling block-ice system. Once the freezing and release cycle is complete, finished blocks are transferred to storage or dispatched to the handling area. Block dimensions, block weight, freezing cycle and safe lifting arrangement must be set against the downstream route.
| Item | Specification / Selection Basis |
| Model | BD200 |
| Nominal ice output | 20,000 kg in 24 hours (20 metric tons per day) |
| Hourly production equivalent | Approximately 833.3 kg/h from the 24-hour rating; not a separate guaranteed hourly test |
| Ice form | Solid ice block 5 to 50 kg |
| Finished block size / weight | Defined at order according to delivery and lifting method |
| Ice-contact material | 316L stainless steel, as stated in the model sheet |
| Other listed stainless parts | 304 stainless steel, as stated in the model sheet |
| Compressor options | Bitzer / RefComp / Hanbell / Frascold; engineering selection at quotation |
| Controls | MCGS PLC-based operation; final HMI features per approved controls list |
| Refrigerant | R404A listed in source sheet; export configuration and destination compliance to be established |
| Power options | 220 V single-phase or 380-415 V three-phase; 50/60 Hz listed as series options; actual suitability depends on model and installation |
| Certification references | CE and ISO 9001 stated in source sheet; request applicable project documents |
| Dimensions / total installed power / weight | Provided in the project-specific technical drawing and quotation |
| Output verification | Performance to be defined for actual ambient and inlet-water or process-fluid conditions |
Technical note: Installed dimensions, power consumption and final equipment options are established by the approved project drawing and quotation.
Primary use
Primary use — Township and regional ice sales. Sell blocks by weight or by truckload to local fisheries and produce markets. A defined block standard simplifies delivery counting, lifting and invoicing. For BD200, preparing for several vessels to call on the same day and coordinating block release with loading crews. Calculate the daily requirement and the busiest withdrawal period before deciding how much ice should be held in reserve.
Additional commercial use
Additional commercial use — Fishing boats and port landings. Supply solid blocks to boats and fish-handling stations that can store and move larger ice units. Coordinate landing and departure schedules with block release and ice stock. At 20 metric tons per day, plan whether the second application uses spare production capacity or needs a separate delivery window.
Other suitable processes
Other suitable processes — Cold-chain transportation and processing-site ice preparation. Stage blocks in appropriate containers for longer product transfer routes. Crush or break blocks at a separate handling point when downstream users require smaller pieces. For each use, document the ice form, hygiene requirements and the route from ice discharge to the actual point of use.
Operation Planning for This Model
A practical operating plan starts with when ice is needed, not when the machine is available to run. For BD200, map the first withdrawal, the most demanding part of the shift and the last planned dispatch. Then check whether planned storage, conveying and shift-based dispatch will protect production from short-term demand spikes. Where ice is used at several points, assign a person to the bin, tank or loading schedule rather than assuming nominal daily production equals instant delivery. Review water condition and equipment cleanliness as part of the regular shift handover.
Commercial and Technical Procurement Considerations
Before purchasing BD200, compare the full cost of delivered ice with on-site manufacture: bought-ice cost, delay risk, staff handling, water and electricity, cleaning, maintenance and storage. Do not assume the machine replaces every cold-chain cost or that the payback period will be the same at different sites. The business case is strongest when the plant can match peak simultaneous withdrawals and changeover periods and avoid repeated supply interruptions. Ask for a quotation that identifies the installation scope, spare parts, warranty conditions and the operating assumptions behind the selected package.
Installation and Production Line Integration
Install the BD200 where operators can reach the electrical isolation point, water or process-fluid supply, cleaning area and ice-discharge route safely. A multi-line or two-shift site normally needs planned storage, conveying and shift-based dispatch. The supporting system may include clean feed water, block handling and lifting equipment, insulated storage and, where customers need loose ice, an appropriate ice-crushing station. Before approving the layout, check drain capacity, access for service, incoming water or liquid quality, ambient design temperature and the length of each conveying or piping run. For multi-line plants, a drawing showing every receiving station and working shift is more useful than positioning the machine by the available floor area alone.
How to Choose Between Neighboring Models
BD200 is rated at 20 metric tons per day. The next smaller BD100 is rated at 10 metric tons per day. It deserves attention when verified peak use stays comfortably below the 20 metric tons class and the smaller installation leaves enough reserve. The next larger BD300 is rated at 30 metric tons per day. Compare it when peak demand, future lines or delivery commitments would run the BD200 close to its nominal daily rating. Use a daily demand curve for the busiest season, the longest shift and any planned additional customers to decide. A smaller machine may cost less to buy yet leave too little reserve; a larger one may add handling and utility costs before the business can use the capacity. The final choice should compare the entire installed ice system, not the ice-machine list price.
Manufacturer Capabilities and Quality Assurance
DAXTRO presents its refrigeration manufacturing work as part of an integrated ice-making, storage and handling offering. The product source materials refer to a 30,000 m² facility in Zhongshan, 316L ice-contact construction, CE/ISO 9001 references and MCGS PLC control. For BD200, ask the supplier to provide the approved general-arrangement drawing, equipment schedule, application-specific material documentation, commissioning scope and maintenance instructions. The purchasing team should also request the model-specific inspection documents and an agreed plan for operator training and spare parts rather than assuming all equipment families have identical paperwork.
Information Needed for an Accurate Quotation
To quote BD200, send DAXTRO the application and expected 20 metric tons-per-day ice need; actual consumption in the busiest shift; peak-season delivery pattern; city and country; summer ambient conditions; incoming water or process-liquid data; and available electrical supply. Also specify clean feed water, block handling and lifting equipment, insulated storage and, where customers need loose ice, an appropriate ice-crushing station, required finished-ice characteristics, storage reserve and the location of the point of use. With those details, the project team can prepare a selected compressor/refrigeration package, utility schedule, layout drawing and an itemized quotation including optional equipment.
What does the 20 ton/day rating mean for BD200?
It is a nominal 24-hour output of 20,000 kg, equivalent to an arithmetic average of 833.3 kg/h. It does not mean that exact production is guaranteed every hour or in every climate. Confirm the test conditions and site-temperature performance in the technical offer.
Who is the BD200 most suitable for?
It is designed as a production class for a busy fishing-port ice plant. In the supplied product positioning, the main use is preparing for several vessels to call on the same day and coordinating block release with loading crews. Verify the busiest operating period and ice-handling route before deciding whether this capacity matches your demand.
What finished direct-cooling block ice specification should I request?
Specify block dimensions and weight according to vessel holds, customer storage bins and the lifting equipment available at the plant.
Which equipment and site details must be confirmed before ordering BD200?
Confirm the final supply voltage and phase, refrigeration package, installed electrical load, footprint, water or process-liquid specification, ice storage, discharge connections and application-specific compliance documents. The series options in the model sheet are not a substitute for an approved project drawing.
When should I choose a different capacity instead of BD200?
The next smaller BD100 is rated at 10 metric tons per day. It deserves attention when verified peak use stays comfortably below the 20 metric tons class and the smaller installation leaves enough reserve. The next larger BD300 is rated at 30 metric tons per day. Compare it when peak demand, future lines or delivery commitments would run the BD200 close to its nominal daily rating. Judge the choice using the highest-demand month and the busiest shift, not the average daily requirement over a year.
What supporting equipment is normally needed?
The full system may need clean feed water, block handling and lifting equipment, insulated storage and, where customers need loose ice, an appropriate ice-crushing station. The exact scope depends on whether ice is used beside the machine, transferred to another production line or dispatched as a commercial product. Ask for the auxiliaries on the same equipment list as the main ice machine.
Request a Technical Proposal
Planning a 20 metric tons-per-day direct-cooling block ice project? Send us your site location, busiest daily ice requirement, available power supply and intended ice-handling process. DAXTRO can review the BD200 equipment choice and prepare a project proposal covering the machine, required auxiliaries, layout and commissioning scope. Request a quotation for the 20 Ton Block Ice Machine today.